+370 612 74427     |      info@ledmada.lt
Ledmada > Products > T8 LED Lamps, G13

T8 LED lamp, G13

Production "T8 LED lamps, G13

T8 fluorescent lamps are now being replaced by LED counterparts everywhere due to their energy efficiency, safety and long life. This does not require replacing the luminaire as a whole. All that is needed is a slight upgrade of the electrical circuit of the existing luminaire and the addition of T8 LED lamps, which are specifically designed for G13 sockets. To make this process as simple as possible, the T8 LED lamps are identical to their fluorescent equivalents and have identical dimensions (diameter 26 mm, length 600 mm/1200 mm/1500 mm)

USE

Industrial lighting, workplace lighting, warehouse lighting, car park lighting, corridor lighting, shop lighting, car wash lighting, garage lighting, common area lighting, other lighting.

BW MODELS

LED SMD2835 140 lm/W Ra80

Dimensions Length 600 mm G13 ∅ 26mm

Colour, CCT 4000K 5000K 6000K

LED model Epistar SMD2835 Ra80

Materials aluminium plastic

Power supply 85V~265VAC 50/60Hz

Galia 9W

Warranty 24 months

Protection IP20 CE

Dimensions Length 1200 mm G13 ∅ 26mm

Colour, CCT 4000K 5000K 6000K

LED model Epistar SMD2835 Ra80

Materials aluminium plastic

Power supply 85V~265VAC 50/60Hz

Galia 18W

Warranty 24 months

Protection IP20 CE

Dimensions length 1500 mm G13 ∅26mm

Colour, CCT 4000K 5000K 6000K

LED model Epistar SMD2835 Ra80

Materials aluminium plastic

Power supply 85V~265VAC 50/60Hz

Galia 25W

Warranty 24 months

Protection IP20 CE

CN MODELS

LED SMD2835 110 lm/W Ra70

Dimensions Length 600 mm G13 ∅ 26mm

Colour, CCT 4000K 5000K 6000K

LED model Epistar SMD2835 Ra70

Materials aluminium plastic

Power supply 85V~265VAC 50/60Hz

Galia 9W

Warranty 24 months

Protection IP20 CE

Dimensions Length 1200 mm G13 ∅ 26mm

Colour, CCT 4000K 5000K 6000K

LED model Epistar SMD2835 Ra70

Materials aluminium plastic

Power supply 85V~265VAC 50/60Hz

Galia 18W

Warranty 24 months

Protection IP20 CE

Dimensions length 1500 mm G13 ∅26mm

Colour, CCT 4000K 5000K 6000K

LED model Epistar SMD2835 Ra70

Materials aluminium plastic

Power supply 85V~265VAC 50/60Hz

Galia 25W

Warranty 24 months

Protection IP20 CE

BW MODELS

LED SMD2835 140 lm/W Ra80

CN MODELS

LED SMD2835 110 lm/W Ra70

Dimensions length 600 mm plinth G13 ∅26mm
LED model Epistar SMD2835 Ra80
Colour, CCT 4000K÷4500K - 5000K÷5500K - 6000K÷6500K
Materials aluminium plastic
Catering 85V~265VAC 50/60Hz
Power 9W
Warranty 24 months
Security IP20 CE
Dimensions length 1200 mm plinth G13 ∅26mm
LED model Epistar SMD2835 Ra80
Colour, CCT 4000K÷4500K - 5000K÷5500K - 6000K÷6500K
Materials aluminium plastic
Catering 85V~265VAC 50/60Hz
Power 18W
Warranty 24 months
Security IP20 CE
Dimensions length 1500 mm plinth G13 ∅26mm
LED model Epistar SMD2835 Ra80
Colour, CCT 4000K÷4500K - 5000K÷5500K - 6000K÷6500K
Materials aluminium plastic
Catering 85V~265VAC 50/60Hz
Power 25W
Warranty 24 months
Security IP20 CE
Dimensions length 600 mm plinth G13 ∅26mm
LED model Epistar SMD2835 Ra70
Colour, CCT 4000K÷4500K - 5000K÷5500K - 6000K÷6500K
Materials aluminium plastic
Catering 85V~265VAC 50/60Hz
Power 9W
Warranty 24 months
Security IP20 CE
Dimensions length 1200 mm plinth G13 ∅26mm
LED model Epistar SMD2835 Ra70
Colour, CCT 4000K÷4500K - 5000K÷5500K - 6000K÷6500K
Materials aluminium plastic
Catering 85V~265VAC 50/60Hz
Power 18W
Warranty 24 months
Security IP20 CE
Dimensions length 1500 mm plinth G13 ∅26mm
LED model Epistar SMD2835 Ra70
Colour, CCT 4000K÷4500K - 5000K÷5500K - 6000K÷6500K
Materials aluminium plastic
Catering 85V~265VAC 50/60Hz
Power 25W
Warranty 24 months
Security IP20 CE

INSTALLATION INSTRUCTIONS

General wiring diagram for a T8 LED lamp

Installation instructions for the luminaire

  1. Switch off the power
  2. Remove the fluorescent lamp
  3. Remove the ballast/wiring cover
  4. Remove ballast
  5. Connect without ballast according to the diagram below
  6. Replace the cord cover
  7. Insert LED lamp
  8. Switch on the power

Warnings, precautions and instructions for use

  • Fluorescent lamps cannot be directly replaced by LED lamps.
  • During installation work, the luminaire's wiring, ballast or other electrical parts may be damaged. Check for damaged wires or components.
  • The installation of the luminaire requires specific knowledge of the luminaire's electrical systems. A qualified electrician must be consulted.
  • To avoid damaging or scratching the wires, do not touch them with sharp objects.
  • DANGER - RISK OF ELECTRIC SHOCK - DISCONNECT THE POWER BEFORE STARTING WORK!
  • Only use luminaires that have appropriate design features and dimensions.

INSTALLATION WORK MAY ONLY BE CARRIED OUT BY A SUITABLY QUALIFIED PERSON WITH A HAZARDOUS WORK PERMIT

DO NOT USE WITH DIMMERS. THIS DEVICE IS NOT INTENDED FOR USE IN EMERGENCY EXIT INSTALLATIONS

Technical DOCUMENTATION

ADDITIONAL INFORMATION

Ledmada UAB
Company code 303287697
VAT code LT100008526416
Kalvarijų g. 125, 3 korpusas, 1 entrance
LT-08221 Vilnius, Lithuania

El. p. info@ledmada.lt
Tel. +370 612 74427

Current account LT947300010138949797
Bank AB "Swedbank", SWIFT: HABALT22

© 2025 | UAB "LEDMADA"